• KARM
  • Contact us
  • E-Submission
ABOUT
ARTICLE TYPES
BROWSE ARTICLES
AUTHOR INFORMATION

Page Path

8
results for

"Electrode"

Filter

Article category

Publication year

"Electrode"

Original Articles
Pain-Related Evoked Potential in Healthy Adults
Kyung Joon Oh, Sung Hoon Kim, Young-Hee Lee, Jong Heon Kim, Hong Sun Jung, Tae Jun Park, Jin Park, Jong Mock Shinn
Ann Rehabil Med 2015;39(1):108-115.   Published online February 28, 2015
DOI: https://doi.org/10.5535/arm.2015.39.1.108
Objective

To investigate the normal data of pain-related evoked potentials (PREP) elicited with a concentric surface electrode among normal, healthy adults and the relationship between PREP and pain intensity.

Methods

Sixty healthy volunteers (22 men and 38 women; aged 36.4±10.7 years; height, 165.4±7.8 cm) were enrolled. Routine nerve conduction study (NCS) was done to measure PREP following electrical stimulation of hands (C7 dermatome) and feet (L5 dermatome). Negative peak (N), positive peak (P) latencies, peak to peak (NP) amplitudes, conduction velocity (CV), and verbal rating scale (VRS) score were obtained. Linear regression analysis tested for significant relevance between variables of PREP and VRS score.

Results

Normal NCS results were obtained in all subjects. N latency of hand PREP was 163.8 ±40.0 ms (right) and 161.0±39.9 ms (left). N latency of foot PREP was 178.0±43.9 ms (right), 180.4±43.4 ms (left). NP amplitude of hands was 20.6±10.6 µV (right) and 21.9±11.6 µV (left). NP amplitude of feet was 18.8±8.3 µV (right) and 19.0±8.4 µV (left). The calculated CV was 13.2±4.7 m/s and VRS score was 3.8±1.0. A highly significant positive correlation was evident between VRS score and NP amplitude (y=0.1069x+1.781, r=0.877, n=60, p<0.0001).

Conclusion

PREP among normal, healthy adults revealed a statistically significant correlation between PREP amplitude and VRS score.

Citations

Citations to this article as recorded by  
  • Conditioned pain modulation and nociception measured by pain-related evoked potentials in patients with polyneuropathy
    Laura Josephine Bubenzer, Julia Jessen, Martin Tegenthoff, Oliver Höffken, Johannes Forsting, Andrea Westermann, Andreas Schwarzer, Elena K. Enax-Krumova, Özüm Simal Özgül
    Frontiers in Neurology.2026;[Epub]     CrossRef
  • Test–retest reliability of intra-epidermal electrically evoked potentials in comparison with other modalities and across stimulation intensities
    Sara U. Júlio, Pascale Rüegge, Miriam Schneuwly, Kevin Hong, Michèle Hubli, Martin Schubert
    Scientific Reports.2025;[Epub]     CrossRef
  • Measurement of Knee Extensor Torque During Repetitive Peripheral Magnetic Stimulation: Comparison of the Forces Induced by Different Stimulators
    Masanori Kamiue, Akio Tsubahara, Tomotaka Ito, Yasuhiro Koike
    Annals of Rehabilitation Medicine.2024; 48(3): 203.     CrossRef
  • An investigation of upper extremity impedance modeling and sensory thresholds in envelope wave electrical stimulation
    Renling Zou, Yuhao Liu, Yicai Wu, Liang Zhao, Jigao Dai, Xiufang Hu, Xuezhi Yin
    Progress in Medical Devices.2024;[Epub]     CrossRef
  • Pain-related evoked potentials with concentric surface electrodes in patients and healthy subjects: a systematic review
    Laura Josephine Bubenzer, Lena Konsolke, Elena Enax-Krumova, Frederic Eberhardt, Martin Tegenthoff, Oliver Höffken, Özüm Simal Özgül
    Brain Structure and Function.2023; 228(7): 1581.     CrossRef
  • Anodal transcutaneous spinal direct current stimulation influences the amplitude of pain-related evoked potentials in healthy subjects
    Frederic Eberhardt, Elena Enax-Krumova, Martin Tegenthoff, Oliver Höffken, Özüm Simal Özgül
    Scientific Reports.2023;[Epub]     CrossRef
  • Intra-epidermal evoked potentials: A promising tool for spinal disorders?
    Robin Lütolf, Sara U. Júlio, Martin Schubert, Michèle Hubli
    Neurophysiologie Clinique.2022; 52(1): 44.     CrossRef
  • Workshops of the eighth international brain–computer interface meeting: BCIs: the next frontier
    Jane E. Huggins, Dean Krusienski, Mariska J. Vansteensel, Davide Valeriani, Antonia Thelen, Sergey Stavisky, James J.S. Norton, Anton Nijholt, Gernot Müller-Putz, Nataliya Kosmyna, Louis Korczowski, Christoph Kapeller, Christian Herff, Sebastian Halder, C
    Brain-Computer Interfaces.2022; 9(2): 69.     CrossRef
  • Acupuncture-Induced Changes in Nociception, Measured by Pain-Related Evoked Potentials: A Pilot Mechanistic Study
    Alexandra Dimitrova, Alisha Harrington, Tab Memmott, Jonathan Sisley, Barry Oken
    Journal of Integrative and Complementary Medicine.2022; 28(11): 862.     CrossRef
  • Slowly conducting potentials in human sensory nerves
    W. Raabe, D. Walk
    Journal of Neuroscience Methods.2021; 351: 109045.     CrossRef
  • Small nerve fiber selectivity of laser and intraepidermal electrical stimulation: A comparative study between glabrous and hairy skin
    Jean-Pascal Lefaucheur, Samar A. Abbas, Isabelle Lefaucheur-Ménard, Denis Rouie, Denise Tebbal, Julie Bismuth, Tarik Nordine
    Neurophysiologie Clinique.2021; 51(4): 357.     CrossRef
  • Classification of Pain Event Related Potential for Evaluation of Pain Perception Induced by Electrical Stimulation
    Kornkanok Tripanpitak, Waranrach Viriyavit, Shao Ying Huang, Wenwei Yu
    Sensors.2020; 20(5): 1491.     CrossRef
  • Application of Referencing Techniques in EEG-Based Recordings of Contact Heat Evoked Potentials (CHEPS)
    Malte Anders, Björn Anders, Matthias Kreuzer, Sebastian Zinn, Carmen Walter
    Frontiers in Human Neuroscience.2020;[Epub]     CrossRef
  • Distraction by a cognitive task has a higher impact on electrophysiological measures compared with conditioned pain modulation
    A. T. L. Do, E. K. Enax-Krumova, Ö. Özgül, L. B. Eitner, S. Heba, M. Tegenthoff, C. Maier, O. Höffken
    BMC Neuroscience.2020;[Epub]     CrossRef
  • Conditioned pain modulation using painful cutaneous electrical stimulation or simply habituation?
    L. Eitner, Ö.S. Özgül, E.K. Enax‐Krumova, J. Vollert, C. Maier, O. Höffken
    European Journal of Pain.2018; 22(7): 1281.     CrossRef
  • High test-retest-reliability of pain-related evoked potentials (PREP) in healthy subjects
    Özüm Simal Özgül, Christoph Maier, Elena K. Enax-Krumova, Jan Vollert, Marc Fischer, Martin Tegenthoff, Oliver Höffken
    Neuroscience Letters.2017; 647: 110.     CrossRef
  • Evoked potentials after painful cutaneous electrical stimulation depict pain relief during a conditioned pain modulation
    Oliver Höffken, Özüm S. Özgül, Elena K. Enax-Krumova, Martin Tegenthoff, Christoph Maier
    BMC Neurology.2017;[Epub]     CrossRef
  • New technologies for the assessment of neuropathies
    Roberto Gasparotti, Luca Padua, Chiara Briani, Giuseppe Lauria
    Nature Reviews Neurology.2017; 13(4): 203.     CrossRef
  • 8,483 View
  • 92 Download
  • 20 Web of Science
  • 18 Crossref
Ulnar Nerve Conduction Study of the First Dorsal Interosseous Muscle in Korean Subjects
Dong Hwee Kim
Ann Rehabil Med 2011;35(5):658-663.   Published online October 31, 2011
DOI: https://doi.org/10.5535/arm.2011.35.5.658
Objective

To derive normative values for ulnar nerve conduction study of the active recording electrode on the first dorsal interosseous muscle (FDI) and the reference electrode on the proximal phalanx of the thumb.

Method

Ulnar nerve motor conduction study with FDI and abductor digiti minimi muscle (ADM) recording was performed in 214 hands of 107 healthy subjects. Ulnar NCS was performed with 2 different recording electrode montages (ADM-base of 5th finger; FDI-thumb) and differences in latency and amplitude were compared. Using this technique, the initial positivity of ulnar compound muscle action potential (CMAP) was not observed in any response with FDI recording.

Results

The maximal values for distal motor latency to the ADM and FDI muscle were 3.8 ms and 4.4 ms, respectively. The maximal difference of distal motor latency between the bilateral FDI recordings was 0.6 ms. The maximal ipsilateral latency difference between ADM and FDI was 1.4 ms.

Conclusion

Placement of the reference electrode on the thumb results in a CMAP without an initial positivity and the normative values obtained may be useful in the diagnosis of ulnar neuropathy at the wrist.

Citations

Citations to this article as recorded by  
  • Design and Validation of a Hand Interossei Muscle Dynamometer (HIMDNA) for Finger Abduction and Adduction Strength Measurement
    Seung Yeon Cho, Geunwu Gimm, Sungwoo Park, Seung Jae Choi, Jaeyoung Kim, Minwoo Cho, Jihyeung Kim, Sungwan Kim
    Annals of Biomedical Engineering.2026;[Epub]     CrossRef
  • Reference Electrode Position Affects Compound Muscle Action Potential Amplitude in Ulnar Nerve Conduction Studies Recorded From the First Dorsal Interosseous Muscle
    Ross Penninkilampi, Catherine Beadon, Con Yiannikas, Matthew Silsby
    Muscle & Nerve.2026;[Epub]     CrossRef
  • Reverse End-to-Side Transfer to Ulnar Motor Nerve: Evidence From Preclinical and Clinical Studies
    Rajesh Krishna Pathiyil, Saud Alzahrani, Rajiv Midha
    Neurosurgery.2023; 92(4): 667.     CrossRef
  • Simulations of active zone structure and function at mammalian NMJs predict that loss of calcium channels alone is not sufficient to replicate LEMS effects
    Scott P. Ginebaugh, Yomna Badawi, Rozita Laghaei, Glenn Mersky, Caleb J. Wallace, Tyler B. Tarr, Cassandra Kaufhold, Stephen Reddel, Stephen D. Meriney
    Journal of Neurophysiology.2023; 129(5): 1259.     CrossRef
  • Localization of Ulnar Neuropathy at the Wrist Using Motor and Sensory Ulnar Nerve Segmental Studies
    Ki Hoon Kim, Beom Suk Kim, Min Jae Kim, Dong Hwee Kim
    Journal of Clinical Neurology.2022; 18(1): 59.     CrossRef
  • Reverse End-to-Side Nerve Transfer for Severe Ulnar Nerve Injury: A Western Canadian Multicentre Prospective Nonrandomized Cohort Study
    Matthew W. T. Curran, Jaret L. Olson, Michael J. Morhart, Simon S. Z. Wu, Raj Midha, Michael J. Berger, K. Ming Chan
    Neurosurgery.2022; 91(6): 856.     CrossRef
  • Split-Hand Syndrome in Amyotrophic Lateral Sclerosis: Differences in Dysfunction of the FDI and ADM Spinal Motoneurons
    Zhi-Li Wang, Liying Cui, Mingsheng Liu, Kang Zhang, Shuangwu Liu, Qingyun Ding
    Frontiers in Neuroscience.2019;[Epub]     CrossRef
  • Ulnar Nerve Entrapment by an Additional Slip of the Triceps Brachii
    Ki Hoon Kim, Jong Woong Park, Byung Kyu Park, Dong Hwee Kim
    American Journal of Physical Medicine & Rehabilitation.2016; 95(10): e159.     CrossRef
  • Thumb performance of elderly users on smartphone touchscreen
    Jinghong Xiong, Satoshi Muraki
    SpringerPlus.2016;[Epub]     CrossRef
  • Ulnar motor study to first dorsal interosseous: Best reference electrode position and normative data
    Ralph M. Buschbacher, Ozun Bayindir, James Malec, Gulseren Akyuz
    Muscle & Nerve.2015; 52(2): 231.     CrossRef
  • 9,786 View
  • 77 Download
  • 10 Crossref

Objective: The purpose of this study was to evaluate the most effective stimulating electrode in TENS for pain relief, and to apply to the treatment of patients with neck and shoulder problems.

Method: The objects were 30 patients with neck and shoulder problems. In 10 of them, insulated needle electrodes were inserted into a trigger point and electrical stimulation given through the electrodes. In 10 of them, non-insulated needle electrodes were applied as the same method. The others were treated with lidocaine injection into a trigger point and electrical stimulation given through the surface electrode. The effects of pain relief were assessed by visual analogue scale (VAS), pain rating score (PRS), and pain algometer.

Result: In the group with insulated needle electrode, the average score was reduced 48.33⁑24.84% in VAS score and 52.00⁑17.55% in PRS, the pressure of pain algometer was increased 34.97⁑15.33%. In non-insulated needle electrode group, reduced 43.16⁑34.62% in VAS score and 43.73⁑34.85% in PRS, the pressure was increased 22.28⁑30.62%. The score reduction of surface electrode group was 20.61⁑15.73% in VAS score and 18.22⁑16.27% in PRS, the pressure-pain threshold increased as 9.05⁑12.81%.

Conclusion: The results suggest that insulated and non-insulated needle electrodes were more effective stimulating electrode in TENS for pain relief than surface electrode.

  • 2,071 View
  • 62 Download
Effect of Different Sites of Recording Electrodes on Auditory Evoked Potentials in Healthy Adults.
Lee, Eun Ha , Kim, Sei Joo
J Korean Acad Rehabil Med 1999;23(2):330-334.

Objective: This study was designed to investigate the effect of different sites of recording electrodes on auditory evoked potentials (AEPs) in healthy adults and to analyse these potentials properly.

Method: Eleven healthy adults, 7 males and 4 females, without any history of disease or conditions causing hearing difficulties were selected. AEPs were performed on these subjects with 4 different methods, i.e. different recording sites, Cz-Ai, Cz-Fpz, Ai-Ac, and Ai-Cs7. Auditory stimulation was given by rarefaction clicks of 75dB intensity and 11.1 Hz frequency, and responses were recorded with surface electrodes.

Results: The amplitudes of peak I and V were larger with vertical recordings, that is the vertex-auricle (Cz-Ai) or vertex-7th cervical spine (Cz-Cs7) recordings, compared to horizontal recordings of both auricle (Ai-Ac) or extracephalic electrodes. The largest amplitude ratio of peak V/I was with vertex-7th cervical spine (Cz-Cs7) recording.

Conclusion: Changes in AEPs with respect to the sites of recording and reference electrodes are thought to be due to the vector of brain stem auditory nuclei and pathways. It might be helpful to consider these changes in the evaluation of brain stem lesions.

  • 1,919 View
  • 2 Download
Comparison of Sensory Nerve Action Potential Parameters Using Different Recording Electrodes.
Pyun, Sung Bom , Ahn, Mikyung , Lee, Hang Jae
J Korean Acad Rehabil Med 2000;24(4):691-695.

Objective: To investigate the influence of five different recording electrodes on the various parameters of sensory nerve action potentials (SNAPs).

Method: Median sensory nerve conduction study was performed in 50 normal subjects using different five types of recording electrodes-disc electrode, ring electrode, bar electrode and two kinds of felt-tip bar electrodes (type 1 and 2). The interelectrode distances between active and reference electrodes were set at 4 cm for the disc and ring electrodes. The bar electrode, felt-tip electrodes type 1 and 2 were fixed at interelectrode distances of 3 cm, 3.7 cm and 2.3 cm, respectively. Onset and peak latency, onset to peak amplitude, peak to peak amplitude and duration of negative spike of SNAPs were measured. These parameters were compared using ANOVA test.

Results: Onset and peak latencies of SNAPs recorded from five different electrodes were not different (p>0.05). Onset to peak and peak to peak amplitudes of SNAPs recorded from felt-tip type 2 electrode were significantly reduced compared to other electrodes (p<0.05). Onset to peak amplitude of SNAPs was also reduced when the ring electrode was used (p<0.05). The negative spike durations of SNAPs recorded from felt-tip type 2 and bar electrodes were shorter than other electrodes recording (p<0.05).

Conclusion: Onset and peak latencies of SNAPs were not affected by the types of electrodes used. Shortening of interelectrode distance may be a main cause of reduction of peak to peak amplitude and negative spike duration of SNAPs.

  • 2,009 View
  • 15 Download
Objective
An electromyographic examination is often utilized to confirm the diagnosis of suprascapular neuropathy in patients with shoulder pain and dysfunction. The purpose of this study was to compare two recording methods (surface and monopolar needle electrode recordings) for the evaluation of suprascapular nerve. Method: Twenty-two healthy subjects were tested with each method. Differences between the recording methods were compared for compound muscle action potential (CMAP) latencies and amplitudes. And the parameters obtained from two recording methods were correlated. Results: The mean age was 43.6⁑12.4 years (range: from 23 to 72 years old). The surface recordings appeared to give a more reproducible latency and amplitude of CMAP of the infraspinatus. The surface recorded CMAP latency and amplitude were 2.58⁑0.46 ms, and 12.6⁑2.7 mV, respectively. Those of the needle electrode recording were 2.49⁑0.41 ms and 27.6⁑6.55 mV, respectively. The two recordings were significantly correlated in latency (r=0.876, p<0.05) and amplitude(r=0.484, p<0.05). Conclusion: Considering the invasiveness of study and compliance of the patient, the surface electrode recording may be prudent for the convenient assessment and follow up studies in suprascapular nerve conduction study. (J Korean Acad Rehab Med 2005; 29: 383-386)
  • 2,863 View
  • 99 Download
Alteration of Sensory Nerve Action Potentials According to the Interelectrode Separation.
Kim, Jae Seong , Kim, Yu Je , Kang, Dae Soo , Park, Dong Sik
J Korean Acad Rehabil Med 2000;24(1):79-82.

Objective: Distance between the active and reference electrodes can affect the waveform configuration and amplitude of sensory nerve action potential (SNAP). This study was purposed to determine the change of SNAP parameters with varying interelectrode distance.

Metohod: Median sensory nerve conduction study was performed in the middle finger of 40 young healthy subjects by antidromic method. To ensure firm contact with skin, strip adhesive electrode was used for recording responses. The active electrode was fixed on 1 cm distal to the proximal flexion crease of middle finger and interelectrode separation was increased from 1 to 5 cm by 1.0 cm increments. Bar electrode was fixed 14 cm proximal from active electrode for stimulation in the wrist area.

Results: As the interelectrode distance increased from 1 cm to 5 cm, onset latency remained unchanged. The peak latency increased with increasing the distance up to 3 cm but didn't change beyond 3 cm (1 cm: 2.89⁑0.89 msec, 2 cm: 2.97⁑0.89 msec, 3 cm: 3.02⁑0.19 msec, 4 cm: 3.02⁑0.19 msec, 5 cm: 3.02⁑0.20 msec). Base-to-peak amplitude significantly increased only up to 3 cm (1 cm: 30.3⁑6.7μV, 2 cm: 43.7⁑8.6μV, 3 cm: 50.8⁑10.4μV, 4 cm: 51.1⁑10.9 μV, 5c m: 51.3⁑11.4μV) but peak-to-peak amplitude sequentially increased to 5 cm (1 cm: 49.6⁑12.1μV, 2 cm: 72.8⁑14.4μv, 3 cm: 83.6⁑19.4μV, 4 cm: 91.3⁑22.5μV, 5 cm: 93.4⁑23.9μV)(p<.05).

Conclustion: This study showed that changing interelectrode distance altered some parameters of SNAP, especially the peak-to peak amplitude.

  • 2,170 View
  • 4 Download
Variations in Motor Nerve Conduction Latency According to Different Recording Electrodes.
Yoon, Joon Shik , Lee, Hang Jae , Kwon, Hee Kyu
J Korean Acad Rehabil Med 1998;22(3):634-636.

Objective: To explore the effects of different recording electrodes on motor nerve conduction latencies.

Method: Median motor conduction study was performed in 10 healthy subjects. Motor conduction latency was determined by placing different recording electrodes (surface disc, monopolar needle and concentric needle) at the motor point of the left abductor pollicis brevis muscle, and reference electrodes on the proximal interphalangeal joint of the thumb. Motor nerve conduction recording was performed by using a surface disc, monopolar needle, and concentric needle. For the intramuscular recordings, needles were inserted both superficially and deep. The stimulus electrodes were secured 8 cm proximal to the recording electrodes, and the same intensity was applied throughout the tests.

Results: Deep intramuscular monopolar and concentric needle electrodes recorded the shorter latencies, 3.0⁑0.4 ms and 3.0⁑0.3 ms, respectively. Superficial concentric needle electrode recorded the longest latency of 3.4⁑0.3 ms. Motor nerve conduction latencies using a surface disc and superficial monopolar electrode were 3.2⁑0.3 ms and 3.2⁑0.3 ms, respectively.

Conclusion: We conclude that the distal motor nerve conduction latency is variable depending on the type of recording electrodes.

  • 1,813 View
  • 1 Download
TOP