Citations
Citations
Citations
Citations
Citations
To evaluate the feasibility of a new position (internal rotation in hanging) in ultrasonography, we compared the length of the glenohumeral joint space and the effectiveness of steroid injection with the hanging position and with the commonly used abdomen or cross position.
A prospective, randomized controlled trial was performed in 42 patients with adhesive capsulitis of shoulder. We used three arm positions for the posterior approach as follows: the patient's palm on thigh, other hand on abdomen (abdomen position); hand on patient's opposite shoulder (cross position); arm in hanging position with internal rotation of shoulder (hanging position). The order of shoulder position was randomized and blinded. Real-time ultrasonography-guided intra-articular steroid injection was performed by posterior approach at the first position in each patient. The Brief Pain Inventory (BPI), the Shoulder Pain and Disability Index (SPADI), and range of motion (ROM) were measured before steroid injection and 2 weeks after injection.
The lengths of the joint space were 2.88±0.75, 2.93±0.89, and 2.82±0.79 mm in abdomen, cross, and hanging position respectively, with no significant difference among the three positions (p=0.429). Treatment efficacy was significantly improved in ROM, total BPI, and SPADI in all three positions (p<0.001). The changes in ROM for shoulder abduction were 23.6°±19.7°, 22.2°±20.9°, and 10.0°±7.8° in abdomen, cross, and hanging position, respectively. Changes in total BPI scores were 25.1±15.7, 23.6.±18.0, 11.6±6.1, and changes in total SPADI score were 35.0±14.2, 30.9±28.9, and 16.5±10.3 in abdomen, cross, and hanging position, respectively. There were no significant difference among the three positions for all parameters (p=0.194, p=0.121, and p=0.108, respectively.
For patients with adhesive capsulitis who cannot achieve or maintain abdomen or cross position, scanning and injection with the shoulder in internal rotation with hanging position may be a useful alternative.
Citations
To compare the clinical outcomes following conservative treatment and arthroscopic repair in patients with a rotator cuff tear.
In this retrospective study, patients aged >50 years with a symptomatic rotator cuff tear were reviewed. The rotator cuff tendons were evaluated using ultrasonography, shoulder magnetic resonance imaging or MR arthrography, and the patients with either a high-grade partial-thickness or small-to-medium-sized (≤3 cm) full-thickness tear were included in this study. The primary outcome measures were a pain assessment score and range of motion (ROM) at 1-year follow-up. The secondary outcomes were the rate of tear progression or retear along with the rate of symptom aggravation after the treatments.
A total of 357 patients were enrolled, including 183 patients that received conservative treatment and 174 patients who received an arthroscopic repair. The pain assessment score (p<0.001) and the ROM in forward flexion (p<0.001) were significantly improved in both groups. The ROM in internal rotation did not significantly change after conservative treatment and arthroscopic repair. The pain assessment score and ROM were not significantly different between the two groups. Retear was observed in 9.6% of patients who had an arthroscopic repair and tear progression was found in 6.7% of those who underwent conservative treatment. The proportion of aggravation for pain and ROM did not significantly differ between the two groups.
The effectiveness of conservative treatment is not inferior to arthroscopic repair for patients >50 years old with a less than medium-sized rotator cuff tear in a 1-year follow-up period. Further study is warranted to find the optimal combination of conservative treatment for a symptomatic rotator cuff tear.
Citations
To assess whether the cognitive function in the acute stage evaluated by domain-specific neuropsychological assessments would be an independent predictor of functional outcome after stroke.
Forty patients underwent 4 domain-specific neuropsychological examinations about 3 weeks after the onset of stroke. The tests included the Boston Naming Test (BNT), the construction recall test (CRT), the construction praxis test (CPT), and the verbal fluency test (VFT). The Korean version of Modified Barthel Index (K-MBI) at 3 months and the modified Rankin Scale (mRS) at 6 months were investigated as functional outcome after stroke. Functional improvement was assessed using the change in K-MBI during the first 3 months and subjects were dichotomized into 'good status' and 'poor status' according to mRS at 6 months. The domain-specific cognitive function along with other possible predictors for functional outcome was examined using regression analysis.
The z-score of CPT (p=0.044) and CRT (p<0.001) were independent predictors for functional improvement measured by the change in K-MBI during the first 3 months after stroke. The z-score of CPT (p=0.049) and CRT (p=0.048) were also independent predictors of functional status at post-stroke 6 months assessed by mRS.
Impairment in visuospatial construction and memory within one month after stroke can be an independent prognostic factor of functional outcome. Domain-specific neuropsychological assessments could be considered in patients with stroke in the acute phase to predict long-term functional outcome.
Citations
Avulsion fracture of the acromion is rare. It is difficult to diagnosis because there is little displacement and it occurs even without direct trauma. We experienced a case without direct trauma that was diagnosed with ultrasonography. A 55-year-old male patient visited our outpatient clinic with shoulder pain resulting from a significant stress at the trapezius muscle during lifting of a steel reinforcement. Simple radiography revealed a calcific deposit over the acromion rather than a fracture. Avulsion fracture was identified with ultrasonography. This is the first report demonstrating that ultrasonography has an advantage over radiographs in the diagnosis of an avulsion fracture of the acromion of the scapula.
Citations
To assess whether the order of test diets influences the results of swallowing studies with regard to their accuracy and safety.
Subjects with suspected dysphagia underwent a videofluoroscopic swallowing study (VFSS) and/or a fiberoptic endoscopic evaluation of swallowing (FEES) and repeated the study on the same day or within a week. The order of test diets comprised of two different sets: trial 1 with the fluid first and trial 2 with the semi-solid food first. Main outcome measurements were the modified penetration-aspiration scale (mPAS) and the pharyngeal residue severity scale (PRSS) for the vallecula and the pyriform sinus.
Sixty-six patients (44 men and 22 women, aged 65.0±15.0 years) were enrolled in this study. Forty-three subjects were evaluated with VFSS only and 23 with both VFSS and FEES. As a result of the swallowing studies, there was no significant difference in each chosen diet sequence regarding mPAS and PRSS. Furthermore, there was no difference regarding the duration of studies, rate of premature study termination, rate of abnormal findings in post-study chest X-ray, and rate of fever or pneumonia post-study.
The accuracy and safety of the swallowing studies do not rely on the order of test diets.
Citations
To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions.
The viscosity of thickened fluid with various concentrations (range, GUA 1%-4%, XAN 1%-6%, STA 1%-7%, at intervals of 1%) was measured with a rotational viscometer with various shear rates (1.29 s-1, 5.16 s-1, 51.6 s-1, and 103 s-1) at a temperature of 35℃, representing body temperature. The viscosity of STA showed time dependent alteration. So STA was excluded. Viscosities of GUA and XAN (range of concentration, GUA 1%-3%, XAN 1%-6%, at intervals of 1%) were measured at a room temperature of 20℃. LST was conducted to compare GUA and XAN (concentration, 1.5%, 2.0%, and 3.0%) at temperatures of 20℃ and 35℃.
The viscosities of 1% GUA and XAN were similar. However, viscosity differences between GUA and XAN were gradually larger as concentration increased. The shear thinning effect, the inverse relationship between the viscosity and the shear rate, was more predominant in XAN than in GUA. The results of LST were not substantially different from GUA and XAN, in spite of the difference in viscosity. However manufacturers' instructions do not demonstrate the rheological properties of thickeners.
The viscosities of thickened fluid were different when the measurement conditions changed. Any single measurement might not be sufficient to determine comparable viscosity with different thickeners. Clinical decision for the use of a specific thickener seems to necessitate cautious consideration of results from a viscometer, LST, and an expert's opinion.
Citations