• KARM
  • Contact us
  • E-Submission
ABOUT
ARTICLE TYPES
BROWSE ARTICLES
AUTHOR INFORMATION

Page Path

1
results for

"Sang Min Lee"

Filter

Article category

Keywords

Publication year

Authors

"Sang Min Lee"

Original Article
Ultrasonographic Evaluation of Needle Insertion Site for the Flexor Pollicis Longus
Seung Min Lee, Kihoon Kim, Sang Min Lee, Hyun Seok Lee
Ann Rehabil Med 2013;37(2):215-220.   Published online April 30, 2013
DOI: https://doi.org/10.5535/arm.2013.37.2.215
Objective

To establish the safest approach to needle electrode insertion into the flexor pollicis longus (FPL) regarding possible needle injury to the superficial radial nerve (SRN) or radial artery by ultrasonography.

Methods

We evaluated 54 forearms of 27 healthy subjects. Three levels were defined in the forearm. Level 1 is the junction of the middle and distal third of the forearm, level 3 is the midpoint of forearm length, and level 2 is the midpoint between two levels. At each level, the distance between the most prominent point of the radius and the SRN (region A), the distance between the SRN and the radial artery (region B), and the depth from the skin surface to the FPL were measured.

Results

The distance of region A was 1.20±0.41 cm in level 1, 1.62±0.45 cm in level 2, and 1.95±0.49 cm in level 3. The distance of region B was 1.02±0.29 cm in level 1, 0.61±0.24 cm in level 2, and 0.37±0.19 cm in level 3. The depth from the skin surface to the FPL was 0.92±0.20 cm in level 1, 1.14±0.26 cm in level 2, and 1.45±0.29 cm in level 3.

Conclusion

The safest needle insertion point to the FPL is the middle of the forearm within approximately 0.8 cm from the most prominent point of the radius. We recommend that the needle is inserted at the above point perpendicular to the skin surface until the needle meets the FPL at a depth of approximately 1.45 cm from the skin surface.

Citations

Citations to this article as recorded by  
  • A Proposed Safe Electromyographic Needle Insertion Technique for the Flexor Pollicis Longus Muscle Using Arterial Pulse Palpation: Preliminary Study with Ultrasonography
    Min Seok Kang, Dong Hwee Kim, Ki Hoon Kim
    Healthcare.2022; 10(11): 2177.     CrossRef
  • Optimal Radial Motor Nerve Conduction Study Using Ultrasound in Healthy Adults
    Jungho Yeo, Yuntae Kim, Sooa Kim, Kiyoung Oh, Hyungdong Kang
    Annals of Rehabilitation Medicine.2017; 41(2): 290.     CrossRef
  • Anatomical Basis of Pronator Teres for Electromyography Needle Placement Using Ultrasonography
    Myung Kyu Park, In Yae Cheong, Ki Hoon Kim, Byung Kyu Park, Dong Hwee Kim
    Annals of Rehabilitation Medicine.2015; 39(1): 39.     CrossRef
  • 5,202 View
  • 40 Download
  • 3 Crossref
TOP